The iko roofing residential cad details below are complete drawings that can easily be downloaded customized for your residential or commercial project and included in your cad library for future use.
Shingle roof flashing details.
Details roofing wrb flashing storm proof roof 2.
Any modifications or changes to the certainteed drawings are the sole responsibility of the roof consultant architect designer or builder and certainteed assumes no responsibility or liability for any such modifications or changes.
Cad details document name pdf dwg download all cad construction details 37 1 mb 3 4 mb mc01 identification of roof areas 694 kb 167 kb mc01a single layer underlayment 678 kb 302 kb mc01b double layer underlayment 711 kb 322 kb mc02 vent pipe flashing 626 kb 349 kb mc03 valley.
Wall flashing with coated metal edge.
Wall with self terminating parapro paraflex 531.
Step flashings are interwoven with the shingles and act essentially as shingles with an upturned leg to allow a transition of the vertical drainage plane of the wall to the drainage plane of the roof.
By downloading and using any arcat cad content you agree to the following license agreement.
To make corner flashing take your tin snips and cut a 45 degree line from an outside corner to the center fold.
Install your underlayment completely and your shingles up to where the wall begins so that the first piece of flashing or the corner flashing will rest on a shingle.
Galvanized steel drip edge flashing in white.
Edge flashing and starter strip roofs peel off from the edges so it is critical to hold them tight with the roof deck sealed on the outside we turn to flashing the edges with metal and membranes metal drip edge flashing details roofing wrb flashing.
The upturned leg of the step flashing is behind the vertical drainage plane or sealed to it with adhesive membrane and sheathing tape.
Flashing requirements for asphalt shingle roofs flashings for asphalt shingles should be corrosion resistant metal with a minimum thickness of 0 019 inch.
Paraguard expansion joint roof to wall with parasolo flashing.
Roof area divider curb type.
At the end of the vertical sidewall the step flashing shall be turned out in a manner that directs water away from the wall and onto the roof and or gutter.
The flashing shall be a minimum of 4 inches 102 mm high and 4 inches 102 mm wide.
Wall base termination detail.
Roofing cad details important.
More product details close 1 1 2 in.
Gibraltar drip edge flashing can be used with asphalt shingles or metal roofing panels.
High wall flashing detail 10 wide sheets.